CGFRN - 8R3671, ANTI-STATIC FLUID, DOCUMENT HANDLER (SUPDAT)

  • MSDS: CGFRN
  • Manufacturer: XEROX CORP
  • Product Name: 8R3671, ANTI-STATIC FLUID, DOCUMENT HANDLER (SUPDAT)
  • National Stock Number: 6850-00N016514
Product Identification

Product ID:8R3671, ANTI-STATIC FLUID, DOCUMENT HANDLER (SUPDAT)
MSDS Date:12/07/1995
FSC:6850
NIIN:00N016514
MSDS Number: CGFRN

Responsible Party
XEROX CORP
100 CLINTON AVE S
ROCHESTER, NY 14644
US

Emergency Phone: 716-422-2177; 714-422-1230

Info Phone: 800-828-6571

Cage: 0E6G9

Contractor
XEROX CORPORATION
ROCHESTER, NY 14644-1877 US

Telephone: 800-828-6571/716-422-2177

Cage: 26921

Ingredients

WATER

CAS: 7732-18-5

RTECS: ZC0110000

Fraction By Weight: >98%

OSHA PEL N/K

ACGIH TLV: N/K


POLY (DIMETHYLSILOXANE); (POLYDIMETHYLSILOXANE)

CAS: 63148-62-9

RTECS: JJ6484500

Fraction By Weight: <0.5%

OSHA PEL N/K

ACGIH TLV: N/K


MONOLAURYLOXY(POLYETHYLENE GLYCOL)

CAS: 61702-78-1

Fraction By Weight: <0.5%

OSHA PEL N/K

ACGIH TLV: N/K


DIMETHYLAMINOETHYLAMINOPROPYL SILOXANE; (SILOXANE AND

CAS: 68554-54-1

Fraction By Weight: <0.5%

OSHA PEL N/K

ACGIH TLV: N/K


DIMETHYLMETHYL(POLYETHYLENE OXIDE) SILOXANE; (SILOXANES AND

CAS: 68937-54-2

Fraction By Weight: <0.5%

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYE IRRITATION NOT AN IRRITANT. SKIN
SENSITIZATION: NOT A SENSITIZER. SKIN IRRITATION: NOT AN IRRITANT.
HUMAN PATCH: NON-IRRITATING, NON-SENSITIZING.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:MAY CAUSE MINIMAL IRRITATION OF RESPIRATORY
PASSAGES ON CONTINUOUS EXPOSURE TO HIGH CONCENTRATIONS.
Medical Cond Aggravated by Exposure:NONE WHEN USED AS DESCRIBED BY
PRODUCT LITERATURE.

First Aid

First Aid:EYES: FLUSH EYES THOROUGHLY WITH WATER FOR AT LEAST 15
MINUTES. SKIN: WASH WITH SOAP AND WATER. INHALATION: REMOVE FROM
EXPOSURE. INGESTION: DILUTE STOMACH CONTENTS WITH SEVERAL GLASSES
OF WATER.

Fire Fighting

Extinguishing Media:MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE.

Accidental Release

Spill Release Procedures:MOP UP OR WASH TO WASTE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP IN CONTAINER SUPPLIED. DO NOT
STORE BELOW FREEZING.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:NONE REQUIRED WHEN USED AS INTENDED IN XEROX
PRODUCTS. NIOSH APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF
CONCERN .
Ventilation:NONE SPECIFIED BY MANUFACTURER.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
MFR'S TRADE NAME/PART #: ANTI-STATIC FLUID. % VOLAT: 99.9 (WT)

Chemical Properties

Boiling Pt:B.P. Text:214F,101C
Vapor Pres:22 @ 20C
Spec Gravity:1 (H*2O = 1)
VOC Pounds/Gallon:20
pH:7.2
Evaporation Rate & Reference:5.1 (N-BUTYLACETATE =1)
Solubility in Water:COMPLETELY
Appearance and Odor:WHITE LIQUID/ODORLESS
Percent Volatiles by Volume:SUPDAT

Stability

Stability Indicator/Materials to Avoid:YES
NONE.
Stability Condition to Avoid:NONE.
Hazardous Decomposition Products:NONE.

Disposal

Waste Disposal Methods:NO SPECIFIC WASTE DISPOSAL METHOD REQUIRED.
DISPOSE OF IN ACCORDANCE WITH FEDERAL, STATE, AND LOCAL
REGULATIONS.

Other Information

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.