BZNST - NICKEL CADMIUM BATTERY, BB-541/U
- MSDS: BZNST
- Manufacturer: BREN TRONICS INC
- Product Name: NICKEL CADMIUM BATTERY, BB-541/U
- National Stock Number: 6140-01-072-1021
Product Identification
Product ID:NICKEL CADMIUM BATTERY, BB-541/U
MSDS Date:03/15/1991
FSC:6140
NIIN:01-072-1021
Kit Part:Y
MSDS Number: BZNST
Responsible Party
COMMACK, NY 11725-3104
US
Emergency Phone: 516-499-5155
Info Phone: 516-499-5155
Cage: 51828
Contractor
Telephone: 631-499-5155
Cage: 51828
Ingredients
NICKEL HYDROXIDE (SARA III)
CAS: 12054-48-7
RTECS: QR7040000
Fraction By Weight: 13-29% %
OSHA PEL 1 MG NI/M3
ACGIH TLV: 0.1 MG NI/M3; 9293
EPA Report Quantity: 10 LBS
DOT Report Quantity: 10 LBS
CADMIUM (SARA III)
CAS: 7440-43-9
RTECS: EU9800000
Fraction By Weight: 11-26% %
OSHA PEL SEE 1910.1027
ACGIH TLV: 0.01 MG/M3 DUST;9394
EPA Report Quantity: 10 LBS
DOT Report Quantity: 10 LBS
COBALT (SARA III)
CAS: 7440-48-4
RTECS: GF8750000
OSHA PEL 0.1 MG/M3;AS CO
ACGIH TLV: 0.05 MG/M3;DUST 9293
POTASSIUM HYDROXIDE (SARA III)
CAS: 1310-58-3
RTECS: TT2100000
Fraction By Weight: <3%
OSHA PEL C, 2 MG/M3
ACGIH TLV: C 2 MG/M3; 9192
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
Hazards
Routes of Entry: Inhalation:NO Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:THESE CHEMICALS ARE CONTAINED IN A
SEALED CAN. RISK OF EXPOSURE OCCURS ONLY IF THE BATTERY IS
MECHANICALLY OR ELECTRICALLY ABUSED. MOST LIKELY, RISK IS WHEN A
CELL LEAKS. KOH IS CAUSTIC AND SKIN CONTA CT CAN CAUSE IRRITATION
OR BURNS. EYE CONTACT WITH KOH MAY CAUSE PERMANENT INJURY.
Explanation of Carcinogenicity:PRODUCT CONTAINS NO MATERIALS CURRENTLY
CLASSIFIED AS CARACINOGENIC BY NTP, IARC OR OSHA PER MFR. SEE SUPP
DATA.
First Aid
First Aid:IF LEAKAGE FROM CELL CONTACT: SKIN-FLUSH WITH WATER, WASH
WITH SOAP AND WATER. IF IRRITATION PERSISTS, CONTACT PHYSICIAN.
EYES-IMMEDIATELY FLUSH WITH COPIOUS AMOUNTS OF WATER FOR 15
MINUTES, THEN SEE PHYSICIAN AT ONCE.
Fire Fighting
Fire Fighting Procedures:FIRE FIGHTERS SHOULD USE SELF-CONTAINED
BREATHING APPARATUS WHEN A LARGE NUMBER OF CELLS ARE INVOLVED.
Unusual Fire/Explosion Hazard:MAY BURST WHEN SUBJECT TO EXTREME HEAT.
CADMIUM FUMES MAY BE RELEASED DURING BURNING.
Accidental Release
Spill Release Procedures:AVOID SKIN AND EYE CONTACT. COLLECT ALL
RELEASED MATERIAL IN PLASTIC BAG FOR WASTE DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:DO NOT SHORT CIRCUIT. STORE IN COOL,
DRY PLACE. USE PROPER BATTERY CHARGER.
Other Precautions:AVOID INCINERATION OR MUTILATION. USE BATTERY IN
PROPER EQUIPMENT. OBSERVE CORRECT POLARITY.
Exposure Controls
Respiratory Protection:AS IN ANY FIRE SITUATION, USE SELF-CONTAINED
BREATHING APPARATUS.
Protective Gloves:WHEN HANDLING LEAKING BATTERIES
Supplemental Safety and Health
EACH CELL IS A SEALED CONTAINER ENCLOSING A NICKEL ELECTRODE, A CADIUM
ELECTRODE, A CADMIUM ELECTRODE AND A POTASSIUM HYDROXIDE ELECTRODE.
Chemical Properties
HCC:Z5
Stability
Stability Indicator/Materials to Avoid:YES
Stability Condition to Avoid:DO NOT HEAT OR DISASSEMBLE. DO NOT SHORT
CIRCUIT.
Hazardous Decomposition Products:DO NOT INCINERATE OR MUTILATE; MAY
BURST OR RELEASE TOXIC MATERIALS.
Disposal
Waste Disposal Methods:DO NOT INCINERATE. DISPOSE OF IN ACCORDANCE WITH
ALL FEDERAL, STATE AND LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.