BWBGM - POLY-TECH LUBRICANT, TEFLON TUBE, 72028
- MSDS: BWBGM
- Manufacturer: AEROSOL SYSTEMS INC
- Product Name: POLY-TECH LUBRICANT, TEFLON TUBE, 72028
- National Stock Number: 9150-00N055453
Product Identification
Product ID:POLY-TECH LUBRICANT, TEFLON TUBE, 72028
MSDS Date:03/09/1992
FSC:9150
NIIN:00N055453
MSDS Number: BWBGM
Responsible Party
MACEDONIA, OH 44056-2013
US
Emergency Phone: 216-467-4195
Info Phone: 216-467-4195
Cage: 2F853
Contractor
Telephone: 330-467-4195 / 330-467-6641
Cage: 2F853
Ingredients
HEXANE (N-HEXANE)
CAS: 110-54-3
RTECS: MN9275000
Fraction By Weight: 37%
OSHA PEL 500 PPM
ACGIH TLV: 50 PPM
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
POLY (DIMETHYLSILOXANE); (SILICONE)
CAS: 63148-62-9
RTECS: JJ6484500
Fraction By Weight: 3%
OSHA PEL N/K
ACGIH TLV: N/K
PROPANE, 2-METHYL-; (ISOBUTANE)
CAS: 75-28-5
RTECS: TZ4300000
Fraction By Weight: 45%
OSHA PEL N/K
ACGIH TLV: 800 PPM (MFR)
PETROLATUM
CAS: 8009-03-8
RTECS: SE6780000
Fraction By Weight: 14%
OSHA PEL N/K
ACGIH TLV: N/K
NON HAZARDOUS INGREDIENTS
Fraction By Weight: 100%
OSHA PEL N/K
ACGIH TLV: N/K
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:MAY CAUSE DIZZINESS OR NARCOSIS IN
HIGH VAPOR CONCENTRATIONS. WILL CAUSE DEFATTING OF SKIN. EFFECTS
ARE REVERSIBLE. LONG TERM EXPOSURE (YEARS) TO HIGH CONC OF VAPOR
MAY CAUSE LUNG, LIVER OR KIDNEY DAM AGE. THE SOLVENTS LISTED HAVE
BEEN REPORTED TO AFFECT CENTRAL NERVOUS SYSTEM. EYE AND SKIN
IRRITANT. (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:ASPIRATION HAZARD IF SWALLOWED. HEXANE
MAY DAMAGE PERIPHERAL NERVE TISSUE. MAY IRRITATE RESPIRATORY TRACT.
INHAL:DIFFICULTY IN BREATHING SKIN-REDNESS. INGEST:VOMITING.
Medical Cond Aggravated by Exposure:HEART DISEASE: RESPIRATORY
DISORDERS
First Aid
First Aid:EYES:WASH WITH WATER FOR AT LEAST 15 MINUTES. SKIN:WASH SKIN
WITH WATER. INGEST:DO NOT INDUCE VOMITING. GASTRIC LAVAGE.
INHAL:GIVE OXYGEN.
Fire Fighting
Flash Point Method:TCC
Flash Point:-160F,-107C
Lower Limits:1.9%
Upper Limits:8.5%
Extinguishing Media:USE WATER FOG, DRY CHEMICAL OR CARBON DIOXIDE.
Fire Fighting Procedures:NIOSH/MSHA APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT . AEROSOL CANS MAY RUPTURE WHEN HEATED.
Unusual Fire/Explosion Hazard:HEATED CANS MAY BURST.
Accidental Release
Spill Release Procedures:USE ABSORBENT SWEEPING COMPOUND TO SOAK UP
MATERIAL. PUT INTO CONTAINER. DISPOSE AS HAZARDOUS WASTE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:KEEP AWAY FROM HEAT, SPARKS OR OPEN
FLAME. STORE AT TEMPERATURES BELOW 120F.
Other Precautions:ENFORCE NO SMOKING.
Exposure Controls
Respiratory Protection:NIOSH/MSHA APPROVED SCBA IF ABOVE TLV LIMIT
EXCEEDING.
Ventilation:LOCAL EXHAUST.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:LONG SLEEVE AND LONG PANTS.
Work Hygienic Practices:DO NOT SMOKE WHILE USING. WASH HANDS AFTER USE.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.
Chemical Properties
HCC:V3
Boiling Pt:B.P. Text:>-12F,>-24C
Vapor Pres:35 PSIG
Vapor Density:4.0
Spec Gravity:0.6 (H*2O=1)
Evaporation Rate & Reference:>1 (BUTYL ACETATE=1)
Solubility in Water:NIL
Appearance and Odor:CLOUDY LIQUID/SOLVENT.
Stability
Stability Indicator/Materials to Avoid:YES
INCOMPATIBLE WITH STRONG OXIDIZERS, ALKALI METALS, INTERHALOGEN
COMPOUNDS.
Stability Condition to Avoid:HIGH TEMPERATURES
Hazardous Decomposition Products:IN FIRE, WILL DECOMPOSE TO CARBON
DIOXIDE AND WATER, SIO*2, HYDROGEN FLUORIDE, AND PERFLUORO
HYDROCARBONS
Disposal
Waste Disposal Methods:DISPOSE AS HAZARDOUS WASTE IN ACCORDANCE WITH
EPA RCRA AND LOCAL, STATE AND FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.