BRZVT - T70CT1, SHER-WOOD (NITROCELLULOSE) LACQUER
- MSDS: BRZVT
- Manufacturer: SHERWIN WILLIAMS CO
- Product Name: T70CT1, SHER-WOOD (NITROCELLULOSE) LACQUER
- National Stock Number: 8010-00N044167
Product Identification
Product ID:T70CT1, SHER-WOOD (NITROCELLULOSE) LACQUER
MSDS Date:01/01/1992
FSC:8010
NIIN:00N044167
MSDS Number: BRZVT
Responsible Party
CLEVELAND, OH 44115-1042
US
Emergency Phone: 216-566-2917
Info Phone: 216-566-2902
Cage: 54636
Contractor
Telephone: 800-251-2486/216-566-2242
Cage: 54636
Ingredients
LIVER, URINARY, BLOOD FORMING, CARDIOVASCULAR & REPRO
RTECS: 9999999ZZ
W/PERM BRAIN & NERVOUS SYS DMG.
RTECS: 9999999ZZ
FEDERAL, STATE & LOCAL REGULATIONS
RTECS: 9999999ZZ
HEATERS. TURN OFF STOVES, ELEC TOOLS &
RTECS: 9999999ZZ
USE APPRVD BONDING & GROUNDING PROC. KEEP CNTNR CLSD
RTECS: 9999999ZZ
W/COMPLETE & APPROP LABELING. DO NOT TAKE
RTECS: 9999999ZZ
HAZ LEVELS ONLY DURING SANDING/ABRADING OF DRIED
RTECS: 9999999ZZ
FROM PROD, UNDERLYING PAINT, OR THE ABRASIVE.
RTECS: 9999999ZZ
NAPHTHOL SPIRITS; (PETROLEUM DISTILLATE); (VM&P NAPHTHA)
CAS: 64742-48-9
Fraction By Weight: 19%
OSHA PEL N/K
ACGIH TLV: N/K
22
CAS: 108-88-3
RTECS: XS5250000
Fraction By Weight: 14%
OSHA PEL 200 PPM/150 STEL
ACGIH TLV: 50 PPM; 9293
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
92
CAS: 67-56-1
RTECS: PC1400000
Fraction By Weight: 4%
OSHA PEL S,200PPM/250STEL
ACGIH TLV: S,200PPM/250STEL; 93
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
33
CAS: 67-63-0
RTECS: NT8050000
Fraction By Weight: 4%
OSHA PEL 400 PPM; 500 STEL
ACGIH TLV: 400 PPM; 500 STEL
ISOBUTYL ALCOHOL; (2-METHYL-1-PROPANOL) (SARA III) VP
CAS: 78-83-1
RTECS: NP9625000
Fraction By Weight: 16%
OSHA PEL 100 PPM
ACGIH TLV: 50 PPM; 9293
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
70
CAS: 78-93-3
RTECS: EL6475000
Fraction By Weight: 4%
OSHA PEL 200 PPM; 300 STEL
ACGIH TLV: 200 PPM; 300 STEL
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
12.5
CAS: 110-96-6
Fraction By Weight: 16%
OSHA PEL N/K
ACGIH TLV: N/K
5.71 LBS/GAL
RTECS: 9999999VO
OSHA PEL N/K
ACGIH TLV: N/K
ING 6 MAY INCR NERVOUS SYS EFTS OF OTHER
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ALCOHOLS & ACETATES CAN BE ABSORBED
THRU SKIN. TO MINIMIZE EXPOS, FOLLOW RECOM FOR PROPER USE, VENT &
PERSONAL PROT EQUIP. ACUTE:IRRIT OF EYES, SKIN & RESP SYS. MAY
CAUSE NERV SYS DEPRESS. EXTREME OVE REXP MAY RSLT IN UNCON & POSS
DEATH. HDCH, DIZZ, NAUS & LOSS OF COORDINATION ARE INDICATIONS OF
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:EXCESSIVE EXPOS TO VAP/SPRAY MIST.
REDNESS & ITCHING/BURNING SENSATION MAY INDICATE EYE/EXCESSIVE SKIN
EXPOS. CHRONIC:TOLUENE APPEARS ON NAVY LISTING OF OCCUP CHEM REPRO
HAZS. SEEK CONSULTATI ON FROM APPROP HLTH PROFESSIONALS CONCERNING
LATEST HAZ LIST INFORMATION & SAFE HNDLG & EXPOS INFORMATION (ING
9)
Medical Cond Aggravated by Exposure:NONE KNOWN.
First Aid
First Aid:INHAL:REMOVE FROM EXPOSURE. RESTORE BREATHING. KEEP WARM &
QUIET. SKIN:WASH AFFECTED AREA THOROUGHLY WITH SOAP & WATER. REMOVE
CONTAMINATED CLOTHING & LAUNDER BEFORE REUSE. EYES:FLUSH WITH LARGE
AMOUN TS OF WATER FOR AT LEAST 15 MINUTES. GET MEDICAL ATTENTION.
INGEST:NEVER GIVE ANYTHING BY MOUTH TO UNCONSCIOUS PERSON. DO NOT
INDUCE VOMITING. GIVE SEVERAL GLASSES OF WATER. SEEK MEDICAL
ATTENTION.
Fire Fighting
Flash Point:23.0F,-5.0C
Lower Limits:0.9%
Upper Limits:36.5%
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM
Fire Fighting Procedures:USE NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP.
WATER SPRAY MAY BE INEFTIVE. IF WATER USED, FOG NOZZ PREF. WATER
MAY BE USED TO COOL CLSD CNTNRS TO (SUPDAT)
Unusual Fire/Explosion Hazard:KEEP CNTNRS TIGHTLY CLSD. ISOLATE FROM
HEAT, ELEC EQUIP, SPARKS & OPEN FLAME. CLSD CNTNRS MAY EXPLODE WHEN
EXPOS TO EXTREME HEAT. APPLICATN TO HOT SURF (SUPDAT)
Accidental Release
Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. VENTILATE AND
REMOVE WITH INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:KEEP AWAY FROM HEAT, SPARKS & OPEN
FLAME. DURING USE & UNTIL ALL VAP GONE:KEEP AREA VENT. DO NOT
SMOKE. EXTING ALL FLAMES, PILOT LIGHTS & (ING 13)
Other Precautions:INTENTIONAL MISUSE BY DELIB CONC & INHAL CONTENTS CAN
BE HARMFUL/FATAL. USE ONLY W/ADEQ VENT. AVOID BRTHG VAP/SPRAY MIST.
DO NOT GET IN/ON SKIN. COATING MAY CONTAIN MATLS CLASSIFIED AS
NUISANCE PARTIC ULATES WHICH MAY BE PRESENT AT (ING 16)
Exposure Controls
Respiratory Protection:IF PERSONAL EXPOS CANNOT BE CONTROLLED < APPLIC
LIM BY VENT, WEAR PROPERLY FITTED NIOSH/MSHA APPRVD ORG
VAP/PARTICULATE RESP. WHEN SANDING/ABRADING DRIED FILM, WEAR
NIOSH/MSHA APPRVD DUST/MIST RESP FO R DUST WHICH MAY BE GENERATED
(ING 17)
Ventilation:LOC EXHST PREF. GEN EXHST ACCEPTABLE IF EXPOS IS MAINTAINED
< APPLIC EXPOS LIM. REFER TO OSHA STDS 1910.94,107,1910.108.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEM SFTY GOGG & FULL LGTH FCSHLD
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
MFR'S TRADE NAME/PART NO:HI BUILD LACQUER GLOSS. FIRE FIGHT PROC:PVNT
PRESS BUILD-UP & POSS AUTOIGNIT/EXPLO WHEN EXPOS TO EXTREME HEAT.
EXPLO HAZ:REQS SPECIAL PREC. DURING EMER CNDTNS OVEREXP TO DECOM P
PRODS MAY CAUSE HLTH HAZ. SYMPS MAY NOT BE IMMED APPARENT. OBTAIN
MED ATTN.
Chemical Properties
HCC:F3
Boiling Pt:B.P. Text:>148F,>64C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Spec Gravity:0.85-0.97
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:72-87
Stability
Stability Indicator/Materials to Avoid:YES
NONE KNOWN.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:BY FIRE:CARBON DIOXIDE, CARBON
MONOXIDE, OXIDES OF NITROGEN, POSSIBLITY OF HYDROGEN CYANIDE.
Disposal
Waste Disposal Methods:WASTE FROM PROD MAY BE HAZ AS DEFINED UNDER RCRA
40CFR 261. WASTE MUST BE TESTED FOR INGIT TO DETERM APPLIC EPA HAZ
WASTE NUMBERS. MAY ALSO REQ TESTING FOR EXTRACTABILITY. INCIN IN
APPRVD FACILITY. DO NOT INCIN CLSD CNTNR. DISPOSE OF I/A/W(ING 12)
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.