BRJPH - ISONATE 125M PURE MDI, 03008

  • MSDS: BRJPH
  • Manufacturer: DOW CHEMICAL USA
  • Product Name: ISONATE 125M PURE MDI, 03008
  • National Stock Number: 6810-00N016685
Product Identification

Product ID:ISONATE 125M PURE MDI, 03008
MSDS Date:12/19/1988
FSC:6810
NIIN:00N016685
MSDS Number: BRJPH

Responsible Party
DOW CHEMICAL USA
2020 DOW CENTER
MIDLAND, MI 48674

Emergency Phone: 517-636-4400;800-424-9300(CHEMTREC)

Info Phone: 517-636-4400

Cage: EO044

Contractor
DOW CHEMICAL USA
MIDLAND, MI 48640-6030 US

Telephone: 800-258-2436

Cage: EO044

Ingredients

LOCAL LAWS & REGS.COMMONLY ACCEPTED METH FOR DISP

RTECS: 9999999ZZ


LANDFILL AFTER SHREDDING/INCINERATION IN APPRVD

RTECS: 9999999ZZ


FACILITY.STEEL DRUMS ARE COMMONLY DISP IN APPRVD

RTECS: 9999999ZZ


CARE.TREATMENT BASED ON JUDGMENT OF PHYSICIAN IN

RTECS: 9999999ZZ


OF RESP SYMP,INCLUDING PULMONARY EDEMA,RESULTING

RTECS: 9999999ZZ


INVOLVED CALL CHEMTREC (800)424-9300.IF

RTECS: 9999999ZZ


OF PROTEIN FOAM (AVAILABLE AT MOST FIRE

RTECS: 9999999ZZ


PUMPED INTO CLSD BUT NOT SEALED CNTNRS FOR

RTECS: 9999999ZZ


ABSORB & SHOVEL INTO OPEN TOP CNTNRS. DO NOT MAKE

RTECS: 9999999ZZ


(OUTSIDE) & TREAT W/NEUTRALIZING SOLN CONSISTING OF

RTECS: 9999999ZZ


OR 5-10% SODIUM CARBONATE.ADD ABOUT 10 PARTS OF

RTECS: 9999999ZZ


ALLOW TO STAND FOR 48 HOURS LETTING EVOLVED CARBON

RTECS: 9999999ZZ


FLOOR USING H*2O/AMMONIA SOLN W/1-2% ADDED

RTECS: 9999999ZZ


LEAST 10 MIN. COVER MOPS & BROOMS USED FOR THIS

RTECS: 9999999ZZ


DRAINED, TRIPLE RINSED, & HOLED TO PVNT

RTECS: 9999999ZZ


OF DRAIN & RINSE FLUID ACCORDING TO FED, STATE &

RTECS: 9999999ZZ


METH IS IN AN APPRVD WASTEWATER TREATMENT

RTECS: 9999999ZZ


DIPHENYLMETHANE DIISOCYANATE (CONTAINING INGREDIENT 2 AT

CAS: 26447-40-5

Fraction By Weight: 100%

OSHA PEL 0.02 PPM

ACGIH TLV: 0.02 PPM


METHYLENE BISPHENYL ISOCYANATE; (4,4'

CAS: 101-68-8

RTECS: NQ9350000

Fraction By Weight: 98%

OSHA PEL 0.02 PPM, C

ACGIH TLV: 0.005 PPM

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


THAT EXPOS TO MDI MAY CAUSE SIMILAR IMPAIRMENT OF

RTECS: 9999999ZZ


ON AVAILABLE DATA, RPTD EXPOS ARE NOT ANTICIPATED TO

RTECS: 9999999ZZ


NUMEROUS IN VITRO (TEST TUBE) MUTAGENICITY STUDIES

RTECS: 9999999ZZ


RPTD IN FEW STUDIES; HOWEVER, MAJORITY HAVE BEEN

RTECS: 9999999ZZ


DIFFICULT, GIVE OXYGEN.CALL A PHYSICIAN.NOTE

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:LD50:ORAL(RAT): >15,000 MG/KG.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYE:MAY CAUSE SLIGHT EYE
IRRITATION.CORNEAL INJ IS UNLIKELY.SKIN:MAY CAUSE ALLERGIC SKIN RXN
IN SUSCEPTIBLE INDIVIDUALS.PRLNGD/RPTD EXPOS MAY CAUSE SKIN
IRRIT.MAY STAIN SKIN.SKIN ABSORB:SINGLE DOSE PR LNGD EXPOS IS NOT
LIKELY TO RSLT IN MATL BEING ABSORBED THROUGH SKIN IN HARMFUL
AMOUNTS.INGEST: (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:SINGLE DOSE ORAL TOXICITY IS LOW.NO
HAZ ANTICIPATED FROM INGEST INCIDENTAL TO INDUSTRIAL
EXPOS.INHAL:MAY CAUSE RESP SENSITIZATION IN SUSCEPTIBLE
INDIVIDUALS. AT ROOM TEMP,VAPS ARE MINIMAL DUE TO LOW VAP PRESS.IF
HEATED/SPRAYED AS AEROSOL,EXCESSIVE CONC ARE ATTAINABLE THAT COULD
BE HAZ ON SINGLE (SUPP DATA)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYES:IRRIGATE W/FLOWING H*2O IMMED & CONTINUOUSLY FOR AT
LEAST 15 MIN.CONSULT MED PERS.DUE TO HIGH VISCOSITY, MATL MAY BE
DFCLT TO REMOVE FROM EYES.SKIN:WASH OFF IN FLOWING
H*2O/SHOWER.INGEST:NO ADVER SE EFTS ANTICIPATED BY THIS ROUTE OF
EXPOS INCIDENTAL TO PROPER INDUSTRIAL HNDLG.CALL MD IMMED
.INHAL:REMOVE TO FRESH AIR.IF NOT BRTHG,GIVE MOUTH-TO-MOUTH
RESUSCITATION.IF BRTHG IS (ING 7)

Fire Fighting

Flash Point Method:PMCC
Flash Point:>350F,>177C
Extinguishing Media:CO*2,DRY CHEM/FOAM.IF H*20 IS USED,IT SHOULD BE IN
VERY LRG QTY.THE RXN BETWEEN H*2O & HOT ISOCYANATE MAY BE VIGOROUS.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:DOWN-WIND PERSONNEL MUST BE EVACUATED.DO
NOT RESEAL CONTAMINATED CONTAINERS SINCE PRESSURE BUILD-UP MAY
CAUSE RUPTURE.

Accidental Release

Spill Release Procedures:EVACUATE AND VENTILATE SPILL AREA, DIKE SPILL
TO PVNT ENTRY INTO WATER SYSTEM, WEAR FULL PROT EQUIP INCLUDING
NIOSH/MSHA APPRVD RESP EQUIP DURING CLEAN UP.MAJOR SPILL:CALL DOW
CHEMICAL U.S.A. (409)238 -2112.IF TRANSPORTATION SPILL (ING 10)
Neutralizing Agent:MIXTURE OF WATER AND 3-8% CONC AMMONIUM HYDROXIDE OR
5-10% SODIUM CARBONATE.

Handling

Handling and Storage Precautions:PROTECT FROM MOISTURE
CONTAMINATION(EXOTHERMIC GENERATION OF CO*2 MAY CAUSE DANGEROUS
PRESSURE.)
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:ATMOSPHERIC LEVS SHOULD BE MAINTAINED BELOW
EXPOS GUIDELINE.WHEN RESP PROT IS REQD FOR CERTAIN OPER,USE
NIOSH/MSHA APPRVD SUPP-AIR RESP.FOR EMERGENCY/OTHER CNDTNS WHERE
EXPOS GUIDELINE GREATLY EXCEEDE D, USE NIOSH/MSHA APPRVD POS PRESS
SCBA.
Ventilation:PROVIDE GEN &/OR LOCAL EXHAUST VENT TO CONTROL AIRBORNE
LEVELS BELOW EXPOSURE GUIDELINES.
Protective Gloves:IMPERVIOUS GLOVES. .
Eye Protection:CHEMICAL WORKERS GOGGLES. .
Other Protective Equipment:BOOTS,APRON,OR FULL-BODY SUIT WILL DEPEND ON
OPERATION.
Work Hygienic Practices:REMOVE CONTAM CLOTHING IMMEDIATELY, WASH SKIN
AREA W/SOAP AND WATER, AND LAUNDER CLOTHING BEFORE REUSE.
Supplemental Safety and Health
VP:3X10 (-4) @ 43C. MATL TO AVOID:INSOLUBLE UREA.COMBINED EFT OF CO*2 &
HEAT CAN PRDCE ENOUGH PRESS TO RUPTURE CLSD CNTNR.EFTS OF
OVEREXP:EXPOS.EXCESS EXPOS MAY CAUSE IRRIT OF EYES,UPPER RESP
TRACT,& LUNGS.EFTS MAY BE DELAYED.DECREASED VENT CAPACITY HAS BEEN
ASSOC W/EXPOS TO SIMILAR ISOCYANATES;IT IS POSS (ING 3)

Chemical Properties

HCC:T4
Boiling Pt:B.P. Text:392F,200C
Decomp Temp:Decomp Text:500F, 260C
Vapor Pres:SUPP DATA
Vapor Density:8.6
Spec Gravity:1.23 @110 F
Solubility in Water:REACTS
Appearance and Odor:WHITE TO YELLOW SOLID AT ROOM TEMPERATURE; LIQUID
ABOVE 100 F, PUNGENT ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
H*2O,ACID,BASE,ALCOHOLS,METAL COMPOUNDS,SURF ACTIVE MATLS.AVOID H*2O AS
IT REACTS TO FORM HEAT,CO*2 & (SUPP DATA)
Stability Condition to Avoid:STORE AS SOLID AT -20 F TO +10 F; AS
LIQUID 105-115 F.
Hazardous Decomposition Products:ISOCYANATE VAPOR AND MIST, CARBON
DIOXIDE, CARBON MONOXIDE, NITROGEN OXIDES & TRACES OF HYDROGEN
CYANIDE.
Conditions to Avoid Polymerization:MAY OCCUR WITH INCOMPATIBLE
REACTANTS, ESPECIALLY STRONG BASES, WATER OR TEMPERATURES OVER 175
C.

Disposal

Waste Disposal Methods:FOLLOW ALL FED,STATE & LOCAL REGS. LIQS ARE
USUALLY INCINERATED IN A PROPER FACILITY.SOLIDS ARE USUALLY
INCINERATED/LANDFILLED.EMPTY DRUMS SHOULD BE FILLED W/H*2O.LET DRUM
STAND UNSEALED FOR 48 HOURS. BEFORE DISP DRUMS SHOULD BE (ING 19)

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.